Autumn 2020
ENGG947
Advanced Building Design for Energy Efficiency and Sustainability
Assignment 2 (Group project – 3 students per group): “Modelling of
design improvements for the 2018 Solar Decathlon Middle East house”
Submission details and dates for assignment 2
• Project report: A day after Week 13, by 11.59pm on Saturday 13th June 2020.
Your report should be submitted on Moodle. All simulation model files should
also be uploaded on Moodle (if size of files is too large you can send the files
with dropbox or any other cloud service). Each report must also contain a
“Group Self Assessment” form which is available from Moodle. Students
should also submit at least a page with meeting minutes that include the dates
groups met, the students present in the meeting (digital meetings, Facebook
chats, or teleconferences count as meetings) and the main points of the
discussion.
• Oral presentation: Those can be preferably pre-recorded and sent to us at the
same time as the report and in the same way (deadline: a day after Week 13, by
11.59pm on Saturday 13th June 2020). If this is a problem then we can simply
organise a suitable time and assess your presentation via ZOOM.
• Please ZIP/compress all of your files in the same folder to ideally submit one
compressed folder rather than many files separately.
Note: This assignment requires significant effort so make sure you start working on it in
advance.
[Penalty for late submission 5% of total assignment mark per calendar day late]
Starting point
In this assignment, you should use the OpenStudio energy modelling software to analyse
design improvements of one of the designs of the Dessert Rose Solar Decathlon house.
Videos with instructions on how to install and use OpenStudio are available on Moodle. A
baseline model has been prepared for you and you can download it from Moodle
(TranslatedPassiveSDMEmodel_2020.osm file) together with the weather file (.epw format)
for the location of the competition.
Tasks
1. The baseline model from Moodle is missing some basic information for the internal
heat gains from occupants, lights and equipment.
Add the following three (3) occupancy scenarios to your baseline model:
i. No occupants;
ii. 2 occupants present all day;
iii. 30 occupants from 9:00AM to 6:00PM and no occupants from 6:00PM to
9:00AM
You should now have three (3) baseline models for the remaining tasks of this
assignment.
2. For all 3 baseline models with the different occupancy scenarios run a simulation
without adding any heating or cooling systems and present meaningful graphs and
statistics of the building thermal performance over the year. You should especially
include the results for the indoor air temperatures and relative humidity % in your
analysis and some discussion of the main findings in relation to the building design.
Make sure the graphs are displayed well and deliver a meaningful message to the
reader. You will need to include the following two (2) periods in your analysis:
a. the annual period of the simulation; and,
b. a hot and humid day. The hot and humid day should be selected from the
climate files by running some preliminary simulations to extra relevant climate
results and the data for the selected day should be summarised in the report
(e.g. graphed).
3. Following the Solar Decathlon rules for thermal comfort (available on Moodle and
online), add an ideal heating and cooling system in your model and determine the
energy required for heating or cooling to bring the temperature and humidity to the
levels required by the competition rules. You will need to provide and discuss the
results for space thermal energy requirements for all 3 baseline models with the
different occupancy scenarios.
4. Suggest and model six (6) building design alternatives (improvements) that would
comply with the competition rules and would at the same time improve the results that
you generated for the baseline designs for points 2 and 3 above. List your
assumptions and discuss your findings. Suggestions that cannot be modelled should
not be included here.
5. Critically discuss any potential drawbacks of the current design in relation to thermal
and energy performance and suggest areas that need improvement.
6. Structure your report in a professional way that provides at least: an introduction of
what you have done for each task; meaningful and clear displays of the results, and; a
critical discussion of the findings from your simulations.
Oral presentation requirements
You will have to give an overview of the findings you describe in the report. Each student
should present for 2.5 – 3 minutes. The presentation counts for 12% of the overall subject
mark.
Format for Report
The maximum length of your report is to be 12 pages of A4 including any
sketches/diagrams/tables and appendices (excluding group self-assessment form and
meeting minutes pages). The mark for the report and the submission of the simulation model
counts for 30% of the overall subject mark.
Each report must also contain a “Group Self Assessment” form (available from Moodle).
Failing to submit the “Group Self Assessment” form will result in a -5% penalty of the total
final assignment mark.
Each report should also include at least a page with meeting minutes from the Group
discussions. This should include the dates groups met, the students present in the meeting
(digital meetings or teleconferences count as meetings) and the main points of the
discussion. There will be a maximum mark of 4% given to the submission of the minutes
(less than 4% could be given if the minutes are very brief and do not include the basic
required information).
Submission of OpenStudio models
Submit all model files, preferably as one compressed file (e.g. zip file), on Moodle. The
model files include: i) the .osm files, and; ii) the whole model folder that has the same name
as the .osm file. The models will be checked during marking to confirm the validity of the
results that you will include in the report. You should include the following files:
• The model files for the 2-occupants baseline model with and without heating (i.e. 2
models: the model used for Task 1 and 2, and the model used for Task 3).
• The model files you developed to discuss potential design improvements in Task 4. If
the file sizes are too large for Moodle you could use alternative ways for submitting
the model files (e.g. submissions with dropbox or Google Drive links will be accepted
in such cases).
ENGG947 Advanced Building Design for Energy Efficiency and Sustainability
Assignment 2
ASSESSMENT CRITERIA FOR ORAL PRESENTATION
Student Names ………………………….
Assessment Mark ………………………….
Assignment 2
“Modelling of design improvements for the 2018 Solar Decathlon house”
Weighting: 12% of the total subject mark
| Group member | ||
| 1 | 2 | 3 |
| Presentation style (clear voice, etc) – 10% |
||
| Visuals (clarity, diagrams, appropriate use of software, etc.) – 30% |
||
| Content and critical analysis of the findings – 50% |
||
| Conclusions – 10% |
ENGG947 Advanced Building Design for Energy Efficiency and Sustainability
Assignment 2
ASSESSMENT CRITERIA FOR WRITTEN REPORT
Student Names ………………………….
Assessment Mark ………………………….
Assignment 2
“Modelling of design improvements for the 2018 Solar Decathlon house”
Weighting: 30% of the total subject mark
| Topic | Max mark % of this assignment |
| Thermal performance results (Task 2); relevance of the presentation and the discussion of the results from Task 2 |
15 |
| Results and discussion for the required space heating/cooling energy in order to achieve the prescribed by the competition thermal comfort targets (Task 3) |
15 |
| Modelling of design alternatives (improvements) and discussion of findings (Task 4) |
42 |
| Discussion of any potential drawbacks of the current design (Task 5) | 8 |
| Validity of thermal simulation models | 5 |
| Group Meeting minutes | 4 |
| Writing/communication and structure (Excellent graphical presentation, style, grammar, spelling, report follows a logical sequence and presented in a professional way, etc.) |
11 |
The post ENGG947 Advanced Building Design appeared first on My Assignment Online.